<table id="iizxl"><meter id="iizxl"><ins id="iizxl"></ins></meter></table>

    1. <input id="iizxl"></input>
        <sub id="iizxl"></sub>
      1. <input id="iizxl"></input>

          24小時在線咨詢
          點擊這里給我發消息 宋先生
          點擊這里給我發消息 鄭先生
          Admesy色度計
          OceanOptics光纖光譜儀
          QSpec科思凱系列
          采樣附件
          光源
          光纖
          美國perkinelmer產品
          P-POptica光譜儀
          臺灣益博思電子防潮箱
          * TMS-PRO透過率測量儀
          * RF-X可定制標準灰板&白板
          * Ocean FX高速采集微型光譜儀
          * Ocean HDX低雜散光微型光譜儀
          * Ocean MZ5中紅外光譜儀
          * Flame光纖光譜儀
          * Auto-TMS全自動透過率測量儀
          * USB2000+光纖光譜儀
          * HR 4000光纖光譜儀
          * ASD2000地物光譜儀

          OceanOptics光纖光譜儀>> 紫外可見光纖光譜儀>>RaySphere太陽光模擬器絕對輻照度測量儀  

          RaySphere太陽光模擬器絕對輻照度測量儀

          Meet the new optical measurement system for absolute irradiance measurements of solar simulators and other radiant sources. The new RaySphere from Ocean Optics measures absolute irradiance over spectral ranges from the UV to the NIR (350 to 1700 nm).

          This portable system is ideal for solar simulator manufacturers and research and development labs as a tool to validate the output of installed solar flashlamps. The flash of a solar simulator is used within the photovoltaic (PV) manufacturing process for the binning of cells according to spectral response and for final PV module efficiency measurements.

          The RaySphere 太陽光模擬器絕對輻照度測量儀 delivers the accuracy and resolution needed to measure and analyze the performance and stability of the flasher with ultralow jitter triggering electronics for timing the measurement to the flashes. Calibration has been validated by an accredited certification lab to ensure accurate detection, enabling evaluation and qualification of the spectral distribution of solar flashers and simulators according to the IEC60904-9 (2007) standard.

          The system includes two thermoelectrically cooled detectors that perform repeatable and accurate spectral analysis of solar flashers from 350 to 1700 nm, and a second version contains a single cooled detector for measurement to 1100 nm.

          RaySphere includes high-speed electronics and an intuitive powerful software interface. Brief measurement times enable detection of a complete spectrum during a flash or even during a portion of the flash. The measurement can be triggered by a fast response photodiode that reacts on the increasing intensity of the flashlight with sub-microsecond response times.

          Trigger Mode

          太陽光模擬器絕對輻照度測量儀Features

          • Intuitive graphical interface
          • Graphical and table display of classification results by wavelength bin
          • Output of actual spectra in mW/cm^2/nm
          • Output of actual measurement and triggering timing with +/- 41 µs resolution
          • Printable classification report

          Under the Hood

            RaySphere RaySphere 1700
          Spectral range: 350-1100 nm 300-1700 nm
          Spectral resolution:

          1.9 nm (FWHM) for 300 - 1100 nm
          12.5 nm (FWHM) for 1100-1700 nm

          Optical input:

          50 mm integrating sphere

          Detector types: TEC stabilized Hamamatsu CCD sensor TEC stabilized Hamamatsu InGaAs sensor
          Dynamic range:

          25000:1 (Back-thinned Si)
          15000:1 (InGaAs)

          Corrected linearity:

          >99.8%

          Minimum integration time:

          8 ms

          Calibration:

          Calibrated for irradiance measurements using national traceable standards (NIST, PTB, CNIM)

          Calibration Accuracy:

          Validated by accredited certification institute, typical values better than 2% accuracy in 400-1100 nm range

          Triggering options:

          Built-in photo trigger, external trigger, manual trigger

          Operating environment:

          Ambient Temperatures 10-35 ºC

          Software:

          Custom Analysis Software for Windows XP, Vista and 7 (32 and 64 bit)

          Communications:

          USB 2.0 high-speed

          Photo-Trigger Specifications

          Jitter (Realtime): <100 ns
          Jitter (Software displayed): 164 µs
          Minimum measurement time: ~9 ms
          Programmable trigger delay: 1040 µs - 168 ms
          Trigger delay increment: 2.56 µs
          Time resolution of display: +/- 41 µs

          相關產品:
          USB2000+光纖光譜儀
          USB4000光纖光譜儀
          Maya2000-Pro紫外可見光纖光譜儀
          HR2000+高分辨率光譜儀
          QE65 Pro最新科研級光纖光譜儀
          版權所有 2007 廣州標旗光電科技發展股份有限公司 www.dufuxian.com
          地址:廣州市蘿崗區廣州科學城彩頻路7號C座701
          電話:(020)38319602 38319620 傳真:(020)38319595 ICP備案:粵ICP備16049535號
          久久99热只有频精品